To balance the need for signage and visual expression with safety and excellence in urban design, provide opportunities for the identification of businesses, organizations and buildings, enable opportunities for advertising to support the local economy, and to prevent excessive Sign proliferation to ensure that effectiveness of informational and identification signage is not undermined.
2.1. | Unless specifically exempt from the requirement to obtain a Development Permit, all Signs and any change to, or relocation of, an existing Sign must comply with the regulations of this Section. |
3.1. | A Sign must be constructed so that it does not: | |||||||||||
|
||||||||||||
3.2. | A Sign must be located so that it does not interfere with Site access or circulation. | |||||||||||
3.3. | Unless otherwise stated in this Bylaw, Signs are not permitted on Fences or Privacy Screens. | |||||||||||
3.4. | A Sign Abutting or above a vehicle access, Driveway, Drive Aisle or path of travel intended for pedestrians and active mobility users, must maintain a minimum vertical clearance of 2.5 m, except that this does not apply to: | |||||||||||
|
|
|||||||||||
3.5. | Signs requiring a Development Permit on a Site with a designated historical resource or that is listed on the Inventory of Historical Resources of Edmonton must be developed to the satisfaction of the Development Planner in consultation with the City department responsible for heritage planning. | |||||||||||
3.6. | Landscaping must not be removed or damaged to: | |||||||||||
|
||||||||||||
3.7. | Despite Subsection 3.6, where the location of a proposed Sign conflicts with existing or approved Landscaping, Landscaping may be removed or relocated provided a Development Permit approving the removal or relocation of the existing or approved Landscaping is issued prior to the Development Permit application for the Sign being approved. | |||||||||||
3.8. | A Sign must not be located on a parked vehicle or trailer on a Site where the primary purpose of the vehicle or trailer is the display of the Sign. | |||||||||||
3.9. | Signs must be constructed so that the structural support elements are designed or concealed so as to appear as an integral part of the overall Sign design. | |||||||||||
3.10. | Signs with Off-premises Advertising and Signs with Digital Copy are not permitted in the civic centre area bounded by 105 Avenue to the north, the North Saskatchewan River Valley to the south, 97 Street to the east, and 100 Street to the west, shown in Appendix I of this Section. | |||||||||||
Sign Illumination Regulations |
||||||||||||
3.11. | The intensity of exposed bulbs on a Sign, excluding Signs with Digital Copy, must not exceed 1100 lumens. | |||||||||||
3.12. | An illuminated Sign must not: | |||||||||||
|
||||||||||||
3.13. | An illuminated Sign that: | |||||||||||
|
||||||||||||
must be turned off daily between 12:00 AM and 5:00 AM. | ||||||||||||
3.14. | Despite Subsection 3.13, a Sign may be illuminated between 12:00 AM and 5:00 AM if the Sign contains On-premises Advertising associated with a business that operates during this period, and only while the business is in operation. | |||||||||||
3.15. | Major Digital Signs and Minor Digital Signs must use automatic light level controls to adjust light levels under darkened outdoor conditions to reduce light pollution, in compliance with the following: | |||||||||||
|
||||||||||||
Separation Distance Regulations |
||||||||||||
3.16. | To minimize Sign proliferation, the following regulations apply: | |||||||||||
|
Table 3.16.3. Separation Distance | ||
---|---|---|
Subsection | Sign Area | Minimum separation distance |
3.16.3.1 | Less than 20.0 m2 | 100 m |
3.16.3.2 | 20.0 m2 to 40.0 m2 | 200 m |
3.16.3.3 | Greater than 40.0 m2 | 300 m |
Maximum Development Permit Duration Regulations
3.17. | The maximum duration of the validity of a Development Permit for Portable Signs with On-premises Advertising is 365 days. | |||||||||||||
3.18. | The maximum duration of the validity of a Development Permit for Portable Signs with Off-premises Advertising is 90 days. | |||||||||||||
3.19. | The maximum duration of the validity for a Development Permit for Major Digital Signs or Minor Digital Signs is 5 years. | |||||||||||||
Measuring Height and Width for Signs |
a | |||||||||||||
3.20. | The Height of a Sign must be measured from the finished ground surface directly under the Sign to the highest point of the Sign, except: | |||||||||||||
|
||||||||||||||
Comprehensive Sign Design Plan |
||||||||||||||
3.21. | The width of a Sign must be measured across the face of the Sign perpendicular to the Height of the Sign, including the structure and other component parts. | a | ||||||||||||
3.22. | A Development Permit for a Comprehensive Sign Design Plan, with a focus on human scale and people-focused Signs and promoting building identity is required for development on: | |||||||||||||
|
||||||||||||||
3.23. | A Comprehensive Sign Design Plan must include coloured plans that identify: | |||||||||||||
|
||||||||||||||
3.24. | In addition to the plans required in Subsection 3.22, a Comprehensive Sign Design Plan must include a statement that explains how the Comprehensive Sign Design Plan: | |||||||||||||
|
||||||||||||||
3.25. | The Signs proposed in the Comprehensive Sign Design Plan must comply with any applicable Sign subsections. | |||||||||||||
3.26. | Where a Development Permit for a Comprehensive Sign Design Plan has been issued, all future Development Permit applications for Signs must comply with the Comprehensive Sign Design Plan. |
Area of Applicability
4.1. | Subsection 4 applies to the following Zones: | ||||||||||||||||
|
|||||||||||||||||
4.2. | Additional Sign regulations may also be listed within the applicable Zone or Specific Development Regulation. In case of a conflict between the regulations in the Zone or Specific Development Regulation and this Subsection, the regulations within the Zone or Specific Development Regulation take precedence. | ||||||||||||||||
Fascia Signs |
|||||||||||||||||
4.3. | A maximum of 1 Fascia Sign is permitted for: | ||||||||||||||||
|
|||||||||||||||||
4.4. | Fascia Signs may be illuminated, except that: | ||||||||||||||||
|
|||||||||||||||||
4.5. | The top of a Fascia Sign must not extend above the Ground Floor. | ||||||||||||||||
4.6. | The maximum Sign Area for Fascia Signs is: | ||||||||||||||||
|
|||||||||||||||||
Freestanding Signs |
|||||||||||||||||
4.7. | A maximum of 2 Freestanding Signs are permitted on a Site with a Development Permit for a non-Residential Use. | ||||||||||||||||
4.8. | Freestanding Signs may be illuminated, except that: | ||||||||||||||||
|
|||||||||||||||||
4.9. | The maximum Sign Area for Freestanding Signs is 3.0 m2. | ||||||||||||||||
4.10. | The maximum Height for Freestanding Signs is 1.8 m. | ||||||||||||||||
Portable Signs with On-premises Advertising |
|||||||||||||||||
4.11. | A maximum of 2 Portable Signs are permitted on a Site with a Development Permit for a: | ||||||||||||||||
|
|||||||||||||||||
4.12. | Portable Signs may be illuminated, except that: | ||||||||||||||||
|
|||||||||||||||||
4.13. | The maximum Sign Area for Portable Signs is 3.0 m2. | ||||||||||||||||
4.14. | The maximum Height for Portable Signs is 1.8 m. | ||||||||||||||||
Projecting Signs |
|||||||||||||||||
4.15. | Each individual non-Residential Use located on the Ground Floor is permitted a maximum of 1 Projecting Sign per building Frontage. | ||||||||||||||||
4.16. | Projecting Signs may be illuminated, except that: | ||||||||||||||||
|
|||||||||||||||||
4.17. | The maximum projection of a Projecting Sign from the building wall is 1.5 m. | ||||||||||||||||
4.18. | The top of a Projecting Sign must not extend above the Ground Floor. | ||||||||||||||||
4.19. | The maximum Sign Area is 3.0 m2. |
Area of Applicability
5.1. | Subsection 5 applies to the following Zones: | |||||||||||||||
|
||||||||||||||||
5.2. | Additional Sign regulations may also be listed within the applicable Zone or Specific Development Regulation. In case of a conflict between the regulations in the Zone or Specific Development Regulation and this Subsection, the regulations within the Zone or Specific Development Regulation take precedence. | |||||||||||||||
General Regulations |
||||||||||||||||
5.3. | No more than 4 total of the following Signs may be permitted on a Site: | |||||||||||||||
|
||||||||||||||||
Fascia Signs |
||||||||||||||||
5.4. | Fascia Signs may be illuminated. | |||||||||||||||
5.5. | No portion of a Fascia Sign may be located above: | |||||||||||||||
|
||||||||||||||||
5.6. | The maximum Sign Area for each individual Fascia Sign is 20.0 m2. | |||||||||||||||
5.7. | The total cumulative Sign Area for all Fascia Signs and Projecting Signs that are parallel to the building wall is a maximum of 50% of the Facade. | |||||||||||||||
5.8. | Despite Subsection 5.5.2, 1 Fascia Sign per Facade may be located above the second Storey if: | |||||||||||||||
|
||||||||||||||||
5.9. | Where Fascia Signs contain Off-premises Advertising: | |||||||||||||||
|
||||||||||||||||
Freestanding Signs |
||||||||||||||||
5.10. | Freestanding Signs may be illuminated. | |||||||||||||||
5.11. | Freestanding Signs must not be located within an Interior Side Setback and must be a minimum of 3.0 m from the Interior Side Lot Line. | |||||||||||||||
5.12. | The maximum Sign Area for Freestanding Signs is 20.0 m2. | |||||||||||||||
5.13. | The maximum Height for Freestanding Signs is 6.0 m. | |||||||||||||||
5.14. | Where Freestanding Signs contain Off-premises Advertising: | |||||||||||||||
|
||||||||||||||||
Portable Signs |
||||||||||||||||
5.15. | Portable Signs may be illuminated. | |||||||||||||||
5.16. | The maximum number of Portable Signs is 5 per Site, except that where the Site Frontage is greater than 300 m the Development Planner may consider a variance to the maximum number of Portable Signs. | |||||||||||||||
5.17. | The maximum Sign Area for Portable Signs is 5.0 m2. | |||||||||||||||
5.18. | The maximum Height for Portable Signs is 3.0 m. | |||||||||||||||
Projecting Signs |
||||||||||||||||
5.19. | Projecting Signs may be illuminated. | |||||||||||||||
5.20. | Where a Projecting Sign is not in the form of a Roof Sign and is oriented perpendicular to the building wall: | |||||||||||||||
|
||||||||||||||||
5.21. | Where a Projecting Sign is not in the form of a Roof Sign and is parallel to the building wall: | |||||||||||||||
|
||||||||||||||||
5.22. | Where a Projecting Sign is in the form of a Roof Sign: | |||||||||||||||
|
||||||||||||||||
Minor Digital Signs and Major Digital Signs |
||||||||||||||||
5.23. | Minor Digital Signs and Major Digital Signs must be located on Sites greater than or equal to 1 ha. | |||||||||||||||
5.24. | The maximum Height of Minor Digital Signs and Major Digital Signs is 6.0 m. | |||||||||||||||
5.25. | The maximum width of Minor Digital Signs and Major Digital Signs is 8.0 m. | |||||||||||||||
5.26. | Minor Digital Signs and Major Digital Signs in the form of a Wall Sign must comply with the following: | |||||||||||||||
|
|
|||||||||||||||
5.27. | Minor Digital Signs and Major Digital Signs in the form of a Ground Sign must comply with the following: | |||||||||||||||
|
Area of Applicability
6.1. | Subsection 6 applies to the following Zones: | |||||||||||||
|
||||||||||||||
6.2. | Additional Sign regulations may also be listed within the applicable Zone or Specific Development Regulation. In case of a conflict between the regulations in the Zone or Specific Development Regulation and this Subsection, the regulations within the Zone or Specific Development Regulation take precedence. | |||||||||||||
General Regulations |
||||||||||||||
6.3. | Where the Site is less than 1 ha, no more than 4 total of the following Signs may be permitted on a Site: | |||||||||||||
|
||||||||||||||
Fascia Signs |
||||||||||||||
6.4. | Fascia Signs may be illuminated. | |||||||||||||
6.5. | No portion of a Fascia Sign may be located: | |||||||||||||
|
||||||||||||||
6.6. | The maximum Sign Area for each individual Fascia Sign is 20.0 m2. | |||||||||||||
6.7. | The total cumulative Sign Area for all Fascia Signs and Projecting Signs that are parallel to the building wall is a maximum of 50% of the Facade. | |||||||||||||
6.8. | Despite Subsection 6.5.2, 1 Fascia Sign per Facade may be located above the second Storey if: | |||||||||||||
|
||||||||||||||
6.9. | Where Fascia Signs contain Off-premises Advertising, they must face an Arterial Road or a Collector Road. | |||||||||||||
Freestanding Signs |
||||||||||||||
6.10. | Freestanding Signs may be illuminated. | |||||||||||||
6.11. | Freestanding Signs must not be located within an Interior Side Setback and must be a minimum of 3.0 m from the Interior Side Lot Line. | |||||||||||||
6.12. | The maximum Sign Area for Freestanding Signs is 20.0 m2. | |||||||||||||
6.13. | The maximum Height for Freestanding Signs is 8.0 m. | |||||||||||||
6.14. | Where Freestanding Signs contain only On-premises Advertising: | |||||||||||||
|
||||||||||||||
6.15. | Where Freestanding Signs contain Off-premises Advertising, they must be located adjacent to an Arterial Road or a Collector Road. | |||||||||||||
Portable Signs |
||||||||||||||
6.16. | Portable Signs may be illuminated. | |||||||||||||
6.17. | The maximum number of Portable Signs is 5 per Site, except that where the Frontage is greater than 300 m the Development Planner may consider a variance to the maximum number of Portable Signs. | |||||||||||||
6.18. | The maximum Sign Area for Portable Signs is 5.0 m2. | |||||||||||||
6.19. | The maximum Height for Portable Signs is 3.0 m. | |||||||||||||
Projecting Signs |
||||||||||||||
6.20. | Projecting Signs may be illuminated. | |||||||||||||
6.21. | The maximum projection from the building wall is 2.0 m. | |||||||||||||
6.22. | Where a Projecting Sign is not in the form of a Roof Sign and is oriented perpendicular to the building wall: | |||||||||||||
|
||||||||||||||
6.23. | Where a Projecting Sign is not in the form of a Roof Sign and is parallel to the building wall: | |||||||||||||
|
||||||||||||||
6.24. | Where a Projecting Sign is in the form of a Roof Sign: | |||||||||||||
|
||||||||||||||
Minor Digital Signs |
||||||||||||||
6.25. | The maximum Height of a Minor Digital Sign is 8.0 m. | |||||||||||||
|
a | |||||||||||||
6.26. | The maximum width of a Minor Digital Sign is 8.0 m. | |||||||||||||
6.27. | Minor Digital Signs in the form of a Wall Sign must comply with the following: | |||||||||||||
|
||||||||||||||
6.28. | Minor Digital Signs in the form of a Ground Sign must comply with the following: | |||||||||||||
|
||||||||||||||
Major Digital Signs |
||||||||||||||
6.29. | The maximum Height of a Major Digital Sign is 8.0 m. | |||||||||||||
6.30. | The maximum width of a Major Digital Sign is 8.0 m. | |||||||||||||
6.31. | Major Digital Signs in the form of a Wall Sign must comply with the following: | |||||||||||||
|
||||||||||||||
6.32. | Major Digital Signs in the form of a Ground Sign must comply with the following: | |||||||||||||
|
Area of Applicability
7.1. | Subsection 7 applies to the following Zones: | ||||||||||
|
|||||||||||
7.2. | Additional Sign regulations may also be listed within the applicable Zone or Specific Development Regulation. In case of a conflict between the regulations in the Zone or Specific Development Regulation and this Subsection, the regulations within the Zone or Specific Development Regulation take precedence. | ||||||||||
General Regulations |
|||||||||||
7.3. | Where the Site is less than 1 ha, no more than 4 total of the following Signs may be permitted on a Site: | ||||||||||
|
|||||||||||
Fascia Signs |
|||||||||||
7.4. | Fascia Signs may be illuminated. | ||||||||||
7.5. | Where a Fascia Sign contains Off-premises Advertising: | ||||||||||
|
|||||||||||
Freestanding Signs |
|||||||||||
7.6. | Freestanding Signs may be illuminated. | ||||||||||
7.7. | The maximum Sign Area for Freestanding Signs is 30.0 m2 except that the Development Planner may vary the maximum Sign Area up to 40.0 m2. | ||||||||||
7.8. | Freestanding Signs must not be located within an Interior Side Setback and must be a minimum of 3.0 m from the Interior Side Lot Line. | ||||||||||
7.9. | The maximum Height for Freestanding Signs is 10.0 m. | ||||||||||
7.10. | Where Freestanding Signs contain Off-premises Advertising, they must be located adjacent to an Arterial Road or a Collector Road. | ||||||||||
Portable Signs |
|||||||||||
7.11. | Portable Signs may be illuminated. | ||||||||||
7.12. | The maximum number of Portable Signs is 5 per Site, except that where the Site Frontage is greater than 300 m the Development Planner may consider a variance to the maximum number of Portable Signs. | ||||||||||
7.13. | The maximum Sign Area for Portable Signs is 5.0 m2. | ||||||||||
7.14. | The maximum Height for Portable Signs is 3.0 m. | ||||||||||
Projecting Signs |
|||||||||||
7.15. | Projecting Signs may be illuminated. | ||||||||||
7.16. | Where a Projecting Sign is not in the form of a Roof Sign and is oriented perpendicular to the building wall: | ||||||||||
|
|||||||||||
7.17. | Where a Projecting Sign is not in the form of a Roof Sign and is parallel to the building wall: | ||||||||||
|
|||||||||||
7.18. | Where a Projecting Sign is in the form of a Roof Sign: | ||||||||||
|
|||||||||||
Minor Digital Signs |
|||||||||||
7.19. | The maximum Height of a Minor Digital Sign is 8.0 m. | ||||||||||
7.20. | The maximum width of a Minor Digital Sign is 8.0 m. | ||||||||||
7.21. | Minor Digital Signs in the form of a Wall Sign must comply with the following: | ||||||||||
|
|||||||||||
7.22. | Minor Digital Signs in the form of a Ground Sign must comply with the following: | ||||||||||
|
|||||||||||
Major Digital Signs |
|||||||||||
7.23. | The maximum Height of a Major Digital Sign is 8.0 m. | ||||||||||
7.24. | The maximum width of a Major Digital Sign is 8.0 m. | ||||||||||
7.25. | Major Digital Signs in the form of a Wall Sign must comply with the following: | ||||||||||
|
|||||||||||
7.26. | Major Digital Signs in the form of a Ground Sign must comply with the following: | ||||||||||
|
Area of Applicability
8.1. | Subsection 8 applies to the following Zones: | ||||||||||||||||
|
|||||||||||||||||
8.2. | Additional Sign regulations may also be listed within the applicable Zone or Specific Development Regulation. In case of a conflict between the regulations in the Zone or Specific Development Regulation and this Subsection, the regulations within the Zone or Specific Development Regulation take precedence. | ||||||||||||||||
Fascia Signs |
|||||||||||||||||
8.3. | Fascia Signs may be illuminated. | ||||||||||||||||
8.4. | The top of a Fascia Sign must not extend above the eaveline or roofline. | ||||||||||||||||
8.5. | The maximum Sign Area for Fascia Signs is 3.0 m2 except that: | ||||||||||||||||
|
|||||||||||||||||
8.6. | A maximum of 25% of the Sign Area may be used for a sponsor’s name or Logo. | ||||||||||||||||
Freestanding Signs |
|||||||||||||||||
8.7. | Freestanding Signs may be illuminated. | ||||||||||||||||
8.8. | Freestanding Signs must be located in a Yard Abutting a Street. | ||||||||||||||||
8.9. | A maximum of 2 Freestanding Signs are permitted on a Site. | ||||||||||||||||
8.10. | Freestanding Signs must not be located within an Interior Side Setback and must be a minimum of 3.0 m from an Interior Side Lot Line. | ||||||||||||||||
8.11. | The maximum Sign Area for Freestanding Signs is 20.0 m2 and the maximum Height is 8.0 m, except that: | ||||||||||||||||
|
|||||||||||||||||
8.12. | A maximum of 25% of the Sign Area may be used for a sponsor’s name or Logo. | ||||||||||||||||
Portable Signs |
|||||||||||||||||
8.13. | Portable Signs may be illuminated. | ||||||||||||||||
8.14. | A maximum of 2 Portable Signs are allowed on a Site. | ||||||||||||||||
8.15. | The maximum Sign Area for Portable Signs is 5.0 m2. | ||||||||||||||||
8.16. | The maximum Height for Portable Signs is 3.0 m. | ||||||||||||||||
Projecting Signs |
|||||||||||||||||
8.17. | Projecting Signs may be illuminated. | ||||||||||||||||
8.18. | The maximum Sign Area for Projecting Signs is 3.0 m2. | ||||||||||||||||
8.19. | The maximum projection from the building wall is 1.5 m. | ||||||||||||||||
8.20. | The top of a Projecting Sign must not extend above the eaveline or roofline. | ||||||||||||||||
Minor Digital Sign |
|||||||||||||||||
8.21. | Minor Digital Signs must face away from Abutting Sites in residential Zones or Sites with existing Residential Uses. | ||||||||||||||||
8.22. | The maximum Height of a Minor Digital Sign is 8.0 m. | ||||||||||||||||
8.23. | The maximum width of a Minor Digital Sign is 8.0 m. | ||||||||||||||||
8.24. | Minor Digital Signs in the form of a Wall Sign must comply with the following: | ||||||||||||||||
|
|||||||||||||||||
8.25. | Minor Digital Signs in the form of a Ground Sign must comply with the following: | ||||||||||||||||
|
Area of Applicability
9.1. | Subsection 9 applies to the following Zones: | ||||||||
|
|||||||||
9.2. | Additional Sign regulations may also be listed within the applicable Zone or Specific Development Regulation. In case of a conflict between the regulations in the Zone or Specific Development Regulation and this Subsection, the regulations within the Zone or Specific Development Regulation take precedence. | ||||||||
9.3. | The Development Planner, when considering a Development Permit application for a Sign, must have regard for all or any of the following: | ||||||||
|
10.1. | Appendix I: Civic Centre Area Boundary |