Queen Mary Park - located to the west of 110 Street NW and south of 109A Avenue NW
Charter Bylaw 19500 (December 8, 2020)
To accommodate a mid-rise residential development with ground-oriented dwellings and the opportunity for limited neighbourhood commercial at the ground level, which supports a pedestrian-friendly streetscape.
This Provision shall apply to the north portion of Lots 2 and 3, Block 10A, Plan 2109HW, located to the west of 110 Street and south of 109A Avenue, as shown on Schedule “A” appended to the Charter Bylaw adopting this Provision, Queen Mary Park.
a. | Convenience Retail Stores |
b. | Live Work Unit |
c. | Lodging Houses |
d. | Major Home Based Business |
e. | Minor Home Based Business |
f. | Multi-unit Housing |
g. | Non-accessory Parking |
h. | Residential Sales Centre |
i. | Specialty Food Services |
j. | Supportive Housing |
k. | Fascia On-premises Signs |
l. | Projecting On-premises Signs |
a. | Specialty Food Services shall not exceed 200 m2 of Public Space indoors. Outdoor seating associated with Specialty Food Services shall be permitted within the west Setback. Outdoor speakers or amplification systems shall be allowed in the outdoor seating associated with Specialty Food Services. |
b. | Signs shall comply with the regulations in Schedule 59B of the Zoning Bylaw. |
c. | A maximum of 10% of any glazing for Commercial Uses may be covered by Signs. The remainder of the glazing shall remain free from obstruction. |
a. | The development shall be in general conformance with the attached Appendices. | ||||||||
b. | The maximum Floor Area Ratio (FAR) shall be 3.0. | ||||||||
c. | The maximum number of Dwellings shall be 125. | ||||||||
d. | The maximum building Height shall be 28.0 m. | ||||||||
e. | Minimum Setbacks shall be as follows: | ||||||||
|
|||||||||
f. | The portions of the Parking Garage below ground level shall not be subject to required Setbacks and may extend to all Lot lines provided there is sufficient soil capacity to support any required Landscaping, to the satisfaction of the Development Officer. This may be achieved by, but is not limited to, the use of planters and other acceptable green roof technologies. | ||||||||
g. | Building Stepbacks shall be as follows: | ||||||||
|
a. | Principal building entrances for any Use shall be designed for universal accessibility. Level changes from the sidewalk to entrances of buildings shall be minimized. Sidewalk furniture and other elements shall be located out of the travel path so as not to obstruct the access to the building. | ||||||||||
b. | A minimum of five (5) Dwellings shall be located at ground level fronting onto 109A Avenue NW and have the following features: | ||||||||||
|
|||||||||||
c. | A minimum of four (4) Dwellings shall be located at ground level facing south and have the following features: | ||||||||||
|
|||||||||||
d. | Commercial Uses shall not be located above the ground floor and shall have an external entrance that is separate from any access to Residential Uses, is universally accessible, and is oriented to face 109A Avenue NW and / or the publicly accessible Amenity Area to the west of the building. | ||||||||||
e. | Architectural treatment of all Façades of the building shall create a unified building exterior. The building shall incorporate design elements to reduce the perceived mass and add architectural interest, including but not limited to: | ||||||||||
|
|||||||||||
f. | All building Façades shall use high quality and durable exterior finishing materials. The use of vinyl siding is prohibited. | ||||||||||
g. | All mechanical equipment, including roof mechanical units, surface level venting systems, and transformers, where permitted, shall be properly barricaded and concealed by screening in a manner compatible with the architectural character of the building or by incorporating it within the building. | ||||||||||
h. | Waste collection, storage areas, and loading shall be located within the building, screened from view from the Abutting public roadway and shall be designed to the satisfaction of the Development Officer in consultation with Waste Management Services, Subdivision, Development Coordination (Transportation) and City Operations. |
a. | Vehicular access to the Site shall be from 109A Avenue NW. | ||||||
b. | Vehicular parking spaces shall be provided in an Underground Parkade. | ||||||
c. | No off-street loading spaces shall be required. | ||||||
d. | Bicycle Parking shall be provided at a rate of 0.5 Bicycle Parking spaces per Dwelling, including: | ||||||
|
a. | A Landscape plan shall be provided by a registered AALA landscape architect and shall include: | ||||
|
|||||
b. | b. A minimum 100 m2 publicly accessible garden or plaza shall be developed on the west side of the building. The plaza shall be allowed in the applicable Setbacks and include seating and lighting and be Landscaped with a mix of coniferous and deciduous shrubs and trees where possible given the underground Parking Garage, in addition to annuals and/or perennials. | ||||
c. | c. An Amenity Area shall be provided above the fourth Storey of the west end of the building for the active or passive recreation and enjoyment of the residents. | ||||
d. | d. Landscaping that extends onto or over City-owned lands shall be developed in accordance with the Traffic Bylaw 5590 and the City Design and Construction Standards to the satisfaction of the Development Officer in consultation with Subdivision and Development Coordination (Transportation). | ||||
e. | e. An arborist report and tree preservation plan to the satisfaction of the Development Officer in consultation with Urban Forestry, shall be submitted with the Development Permit application to determine the impact of the proposed development, including excavation and construction, on the existing boulevard trees along 109A Avenue NW. If required by the Development Officer, an air spading tool shall be used to determine the amount and size of roots that may need to be cut for the foundation wall. If: | ||||
|
|||||
f. | An exterior lighting plan shall be required as part of the Development Permit application. Decorative and security lighting shall be designed and finished in a manner consistent with the architectural theme of the development and shall be provided to ensure a well-lit and safe environment for pedestrians. | ||||
g. | All exterior lighting of the Site shall be designed so that the lighting is directed away from adjacent residential development and illumination shall not extend beyond the boundaries of the Site. Night-time light pollution shall be reduced by avoiding over-illumination of the development and by using exterior lighting fixtures that are full cut-off in design to direct light downward. |
a. | Prior to the issuance of a Development Permit for: | ||||||||||||||
|
|||||||||||||||
b. | As a condition of the Development Permit for construction of a principal building, the owner shall enter into an agreement with the City of Edmonton for off-site improvements necessary to serve or enhance the development, such improvements to be constructed at the owner’s cost. The agreement process includes an engineering drawing review and approval process. Improvements to address in the agreement include, but are not limited to: | ||||||||||||||
|
|||||||||||||||
c. | A minimum of four (4) Dwellings shall be suitable for families by meeting the following criteria: | ||||||||||||||
|