To accommodate the development of a range of commercial and institutional uses with additional opportunity for a complementary mix of residential in the form multi-unit housing.  This establishes a high quality urban environment,that is well integrated with the adjacent Ambleside commercial and residential areas and to create an aesthetic and architecturally appealing development adjacent to Anthony Henday Drive.

The provision shall apply to portions of Lot 1, Block 14, Plan 0723371, containing approximately 2.8 ha, immediately south west of Anthony Henday Drive and north east of Windermere Boulevard SW, Ambleside Neighbourhood, as shown on Schedule "A” of the Bylaw adopting this Provision.

a. Animal Hospital and Shelters
b. Apartment Hotels
c. Automotive and Equipment Repair Shops
d. Automotive and Minor Recreation Vehicle Sales / Rentals
e. Bars and Neighbourhood Pubs
f. Breweries, Wineries and Distilleries
g. Business Support Services
h. Cannabis Retail Sales
i. Child Care Services
j. Commercial Schools
k. Community Recreation Services
l. Convenience Retail Stores
m. Convenience Vehicle Rentals, when designed as an integral component of a Hotel
n. Creation and Production Establishments
o. Drive-in Food Services
p. Gas Bars
q. General Industrial Uses
r. General Retail Stores
s. Government Services
t. Greenhouses, Plant Nurseries and Garden Centres
u. Health Services
v. Hotels
w. Indoor Participant Recreation Services
x. Liquor Stores
y. Live Work Unit
z. Market
aa. Media Studios
bb. Minor and Major Amusement Establishments
cc. Minor Home Based Business
dd. Major Home Based Business
ee. Minor Service Stations
ff. Mobile Catering Food Services
gg. Multi-Unit Housing
hh. Nightclubs
ii. Outdoor Participant Recreation Services
jj. Personal Service Shops
kk. Private Clubs
ll. Professional, Financial and Office Support Services
mm. Protective Emergency Services
nn. Private Education Services
oo. Public Libraries and Cultural Exhibits
pp. Rapid Drive-Through Vehicle Services
qq. Recycling Depots
rr. Religious Assembly
ss. Residential Sales Centre
tt. Restaurants
uu. Secondhand Stores
vv. Secondary Suites
ww. Special Events
xx. Speciality Food Services
yy. Spectator Entertainment Establishments
zz. Urban Gardens
aaa. Veterinary Services
bbb. Warehouse Sales
ccc. Minor Digital Off-premises Signs
ddd. Minor Digital On-premises Signs
eee. Minor Digital On-premises Off-premises Signs
fff. Fascia Off-premises Signs
ggg. Fascia On-premises Signs
hhh. Freestanding On-premises Signs
iii. Projecting On-premises Signs
jjj. Temporary On-premises Signs
a. Notwithstanding Section 720.3.2 a Site plan is not appended to this Provision.
b. With build-out of the Site, Uses shall be part of a purpose-designed mixed-use development characterized by: 
 
i. predominantly commercial development in the form of low, medium and/or high-rise buildings, complemented with business, institutional and/or residential Uses; and/or 
ii. stand alone row housing or mixed-use mid to high-rise buildings for hotel, apartment and/or office related development.
c. Floor Area Ratio:
 
i. the maximum total Floor Area Ratio for all combined Uses for the Site shall be 2.5, except that the maximum total Floor Area Ratio for all combined Uses for the Site Shall be 3.0 where buildings are designed to accommodate mixed uses in a vertical format, and ground floor commercial and/or business uses are provided;
ii. the maximum Floor Area Ratio for commercial and business Uses shall be 1.0, except that Apartment Hotels, Hotels, Business Support Services and Professional, Financial and Office Support Services shall be 3.0;
iii. the maximum Floor Area Ratio for General Industrial Uses shall be 3.0; and
iv. the maximum total Floor Area Ratio for Multi-unit Housing shall be 3.0.
d. The maximum Building Height shall not exceed 14.0 m, with the exception  that for high rise buildings the primary Uses are one of or a mix of the following Uses, the maximum Building Height shall not exceed 60.0 m:
 
i. Apartment Hotels
ii. Multi-unit Housing
iii. Business Support Services
iv. Government Services
v. Health Services
vi. Hotels
vii. Professional, Financial and Office Support Services
e. A minimum contiguous landscaped Setback of 3.0 m shall be required where the site borders on Anthony Henday Drive.
f. A minimum contiguous landscaped Setback of 3.0 m shall be required where the Site abuts Windermere Boulevard.
g. A detailed Landscaping plan shall be submitted in accordance with Section 55 of the Zoning Bylaw, 12800, prior to the approval of any development permit. This plan shall include pedestrian connection and fencing details, exterior lighting and street furniture elements, pedestrian seating areas, varied sizes and species of new plantings.
h. All landscaped Yards and Setbacks shall contain minimum plantings as outlined in the following:
 
i. one tree for each 17.5 m2 and one shrub for each 10 m2 of any required Yard or Setback at grade.
i. All planting shall conform to the following:
 
i. the proportion of deciduous to coniferous trees and shrubs shall be approximately 50:50 and the following mix of tree sizes shall be used;
ii. 100% of required deciduous trees shall be a minimum 75 mm caliper; and
iii. 75% of required coniferous trees shall be a minimum of 2.5 m in height and 25% shall be a minimum 3.5 m in height.
j. No parking, loading, storage, trash collection, outdoor service or display area shall be permitted within a required Setback. Loading, storage and trash collection areas shall be located to the rear or sides of the principal building and shall be screened from view from any adjacent Sites, public roadways or Light Rail Transit lines, in accordance with the provisions of subsection 55.4 of the Zoning Bylaw, 12800. If the rear or sides of a Site are used for parking, an outdoor service or display area, or both, and Abut a Residential Zone or a Lane serving a Residential Zone, such areas shall be screened in accordance with the provisions of subsection 55.4 of the Zoning Bylaw, 12800.
k. Nightclubs shall:
 
i. only be permitted when designed as a secondary component to a Hotel; and
ii. shall be limited to less than 200 occupants and 240 m² of Public Space.
l. General Industrial Uses shall:
 
i. be limited to facilities commonly referred to as self-storage and shall be contained within an enclosed building; and 
ii. be separated a minimum of 50 m from any Residential or Residential-related Use.
m. No single General Retail Store shall exceed 5,000 m2 of floor area.
n. No single Warehouse Sales shall exceed 5,000 m2 of floor area.
o. Gas Bars and Minor Service Stations shall be located not less than 15.0 m from any Residential or Residential-related Use. This distance shall be measured from the closest pump island, fill pipes, vent pipes, drive-through vehicle service or service station to the Residential or Residential-related Use. This Setback distance may be reduced at the discretion of the Development Officer if the Development Officer is satisfied that impacts on the Residential or Residential-related Use will be minimal due to structural and design measures incorporated into the proposed development.
a. Building Design and Architectural Standards:
 
i. An architectural theme shall be established for the entire Site to ensure consistency of design elements such as building design, layout, finishing materials and colours, signage and landscape treatments.
ii. Any canopies shall be designed and finished in a manner consistent with the design and finishing of the principal building.
iii. Design techniques including, but not limited to, the use of sloped roof, variations in building setbacks and articulation of building facades shall be utilized in order to minimize the perception of massing of the building when viewed from adjacent Sites and public roadways.
iv. Building facades (all sides) shall include design elements, finishing materials and variations that will reduce any perceived mass and linearity of large buildings and add architectural interest.
v. The roof line of buildings shall consist of sloped roofs of varying pitches which may be finished in any combination of metal, wood shakes, asphalt shingles, clay tiles, or roof materials having a similar texture and appearance or flat roofs where they are concealed by parapet walls that include articulation and use of design elements that are in harmony with the principal architectural theme that reduce any perceived mass and linearity of large buildings and add architectural interest;
vi. To reduce any perceived mass and linearity of large buildings and add architectural interest, the exterior finishing materials shall incorporate vertical elements using a combinations of brick, stone or other masonry materials, concrete, stucco, glazing or siding, having a similar character, with wood or metal trim, having regard to the objective of ensuring that the development is of a high quality and complementary theme. Abrupt and excessive differences in scale of adjacent buildings shall be minimized through transitional building treatment.
vii. Primary emphasis shall be placed on design elements and façade enhancements, particularly to the first and second levels of buildings to create a pedestrian friendly environment. Lower floors shall be articulated to add variety, interest and a human scale dimension. Recommended design elements include placement of windows to allow for viewing into the building by pedestrians; transparency of windows; wall niches; entrance features; street furniture; canopies and features that lend visual interest and create a human scale.
viii. Smaller buildings shall incorporate complementary materials and architectural detailing to be consistent with the larger buildings.
ix. Functional and decorative lighting shall be provided within the development to enhance the appearance of the Site and buildings.
x. Any building backing on to Anthony Henday Drive or fronting onto Windermere Boulevard shall use special architectural treatment for building corners.
xi. Any single wall length greater than 15.0 m visible from a public road shall use articulation in the wall to minimize the perceived mass of the building.
xii. Building entrances shall be readily identifiable by using design elements such as distinctive materials and colours, human scale architecture, recessing, canopies, awnings, overhangs, articulation, projections and columns.
xiii. All mechanical equipment, including roof mechanical units, shall be concealed by screening with design elements that are compatible or complement the architectural character and materials of the building, or concealed by incorporating it within the building framework.
b. Pedestrian Environment
 
i. The development shall create a pedestrian friendly environment, which may include a combination of:
 
A. entrance feature(s)
B. pedestrian/directional signage
C. outdoor seating areas
D. canopies
E. landscaping and street furniture
F. convenient access to parking
G. public art
H. small parks, squares, plazas and/or greens
ii. Development within this site shall ensure that the design of the pedestrian environment is comfortable, convenient, visually attractive and safe for human activity.
iii. Pedestrian pathways to building entrances, amenities and transit shall be convenient, safe and well lit, with special paving or landscaping to define the connections.
iv. Safe pedestrian connections shall be provided from the Site to Windermere Boulevard.
c. Access, Circulation and Parking
 
i. Internal and perimeter streets shall be tree lined and lit with appropriate lighting.
ii. Developments shall provide walkways along primary buildings.
iii. Parking areas shall be designed for safe and orderly movement.
iv. Parking areas shall be designed to minimize pedestrian/vehicular conflict.
v. Parking areas adjacent to Windermere Boulevard shall include landscaping between the roadway and parking stalls to create an aesthetic buffer and to reduce visual impact.
vi. Structured parking shall complement the architectural features of the adjacent building(s).
vii. No structured parking shall front onto Windermere Boulevard.
d. Landscaping
 
i. Open space shall feature high quality landscape architecture intended to make spaces comfortable and enjoyable including such features as trees, street furniture and public art.
ii. Coordinated and complementary streetscape enhancements shall be applied, including street trees, fencing, pedestrian scaled lighting, street furniture and other amenities.
iii. Landscaping shall be used to highlight major circulation patterns, pedestrian pathways and to provide cohesiveness to the overall development.
iv. Landscaping of the Site shall include plant materials that provide colour and texture throughout the year to enhance the appearance during non-growing months.
v. Landscaping shall complement the overall Site and include a combination of plant material that provides visual interest.
vi. Site landscaping shall be used to soften the building form.  Recommended landscaping treatments may include one or a combination of tree and shrub planting, water features, railings, curbs, low walls, fences, berms, walkways, amenity areas and public art.
vii. A Site entry feature is required at the primary all directional access to the Site along Windermere Boulevard. This entry feature shall include trees and shrubs, accents, paving treatments, lighting and/or compatible architectural elements.
viii. Along Anthony Henday Drive, the rear of the Site shall reflect a formalized landscape treatment to break-up the façade of building walls, enhance views and screen parking lots, and service areas from the traveling public.
ix. A 1.2 m continuous screen fence shall be located within private property lines along the portion of the Site adjacent to Anthony Henday Drive.
e. Signage
 
i. A Comprehensive Sign Design Plan and Schedule shall be submitted, consistent with the overall intent of subsection 59.3 of the Zoning Bylaw, 12800, prior to the approval of any development permit.
ii. Signs shall be designed to reflect an aesthetically pleasing and cohesive approach to complement the architectural features of all buildings.
iii. Individual business identification signs located on the façades of buildings shall be similar in proportion, construction materials and placement. The design, scale and placement of signs shall be such that the signage does not detract from the overall appearance of the development and that the signage is not obtrusive, having regard to the scale of the buildings on the Site and to the distance of the building Setback.
iv. Directional signage shall provide wayfinding information at critical locations relating to tenants, pedestrian movement, parking lots, loading zones and pick up areas, entrances, exits and amenity areas.
v. Movement and brightness of signage shall be designed to minimize light pollution and visual intrusion on surrounding residential properties.
vi. Signs shall comply with the regulations found in Section 59 and Schedule 59E of this Bylaw, with the intent to complement the pedestrian-oriented commercial environment.
vii. The maximum Height of a Freestanding Sign shall be 8.0 m, except that:
 
A. One additional Freestanding On-premises Sign shall be allowed along the north property line of the site, to a maximum height of 15.0 m, with a maximum Sign Area of 52 m2. 
f. CPTED
 
i. CPTED principles shall be used to design all public and private spaces and facilities that focus natural surveillance and access control to lessen the likelihood of crime within the Site.
a. Pedestrians should be protected from the weather through the provision of canopies, awnings, overhangs or covered walkways where practical.
b. Buildings located adjacent to Windermere Boulevard are encouraged to be designed with active frontages and to provide building entry-ways facing Windermere Boulevard for direct pedestrian access to the public street.