a. |
Notwithstanding Section 720.3.2 a Site plan is not appended to this Provision. |
b. |
With build-out of the Site, Uses shall be part of a purpose-designed mixed-use development characterized by: |
|
i. |
predominantly commercial development in the form of low, medium and/or high-rise buildings, complemented with business, institutional and/or residential Uses; and/or |
ii. |
stand alone row housing or mixed-use mid to high-rise buildings for hotel, apartment and/or office related development. |
|
c. |
Floor Area Ratio: |
|
i. |
the maximum total Floor Area Ratio for all combined Uses for the Site shall be 2.5, except that the maximum total Floor Area Ratio for all combined Uses for the Site Shall be 3.0 where buildings are designed to accommodate mixed uses in a vertical format, and ground floor commercial and/or business uses are provided; |
ii. |
the maximum Floor Area Ratio for commercial and business Uses shall be 1.0, except that Apartment Hotels, Hotels, Business Support Services and Professional, Financial and Office Support Services shall be 3.0; |
iii. |
the maximum Floor Area Ratio for General Industrial Uses shall be 3.0; and |
iv. |
the maximum total Floor Area Ratio for Multi-unit Housing shall be 3.0. |
|
d. |
The maximum Building Height shall not exceed 14.0 m, with the exception that for high rise buildings the primary Uses are one of or a mix of the following Uses, the maximum Building Height shall not exceed 60.0 m: |
|
i. |
Apartment Hotels |
ii. |
Multi-unit Housing |
iii. |
Business Support Services |
iv. |
Government Services |
v. |
Health Services |
vi. |
Hotels |
vii. |
Professional, Financial and Office Support Services |
|
e. |
A minimum contiguous landscaped Setback of 3.0 m shall be required where the site borders on Anthony Henday Drive. |
f. |
A minimum contiguous landscaped Setback of 3.0 m shall be required where the Site abuts Windermere Boulevard. |
g. |
A detailed Landscaping plan shall be submitted in accordance with Section 55 of the Zoning Bylaw, 12800, prior to the approval of any development permit. This plan shall include pedestrian connection and fencing details, exterior lighting and street furniture elements, pedestrian seating areas, varied sizes and species of new plantings. |
h. |
All landscaped Yards and Setbacks shall contain minimum plantings as outlined in the following: |
|
i. |
one tree for each 17.5 m2 and one shrub for each 10 m2 of any required Yard or Setback at grade. |
|
i. |
All planting shall conform to the following: |
|
i. |
the proportion of deciduous to coniferous trees and shrubs shall be approximately 50:50 and the following mix of tree sizes shall be used; |
ii. |
100% of required deciduous trees shall be a minimum 75 mm caliper; and |
iii. |
75% of required coniferous trees shall be a minimum of 2.5 m in height and 25% shall be a minimum 3.5 m in height. |
|
j. |
No parking, loading, storage, trash collection, outdoor service or display area shall be permitted within a required Setback. Loading, storage and trash collection areas shall be located to the rear or sides of the principal building and shall be screened from view from any adjacent Sites, public roadways or Light Rail Transit lines, in accordance with the provisions of subsection 55.4 of the Zoning Bylaw, 12800. If the rear or sides of a Site are used for parking, an outdoor service or display area, or both, and Abut a Residential Zone or a Lane serving a Residential Zone, such areas shall be screened in accordance with the provisions of subsection 55.4 of the Zoning Bylaw, 12800. |
k. |
Nightclubs shall: |
|
i. |
only be permitted when designed as a secondary component to a Hotel; and |
ii. |
shall be limited to less than 200 occupants and 240 m² of Public Space. |
|
l. |
General Industrial Uses shall: |
|
i. |
be limited to facilities commonly referred to as self-storage and shall be contained within an enclosed building; and |
ii. |
be separated a minimum of 50 m from any Residential or Residential-related Use. |
|
m. |
No single General Retail Store shall exceed 5,000 m2 of floor area. |
n. |
No single Warehouse Sales shall exceed 5,000 m2 of floor area. |
o. |
Gas Bars and Minor Service Stations shall be located not less than 15.0 m from any Residential or Residential-related Use. This distance shall be measured from the closest pump island, fill pipes, vent pipes, drive-through vehicle service or service station to the Residential or Residential-related Use. This Setback distance may be reduced at the discretion of the Development Officer if the Development Officer is satisfied that impacts on the Residential or Residential-related Use will be minimal due to structural and design measures incorporated into the proposed development. |